Finned Top modules feature a top design equipped with heat dissipation fins. The integrated top heatsink enhances cooling efficiency when handling massive data."}},{"@type":"Question","name":"What kind of optical fiber do I need to use with the 800G Twin-Port NDR 2xSR4 optical module?","acceptedAnswer":{"@type":"Answer","text":"When the connection rate of both devices is 2x400G-2x400G, it is paired with two OM4 MPO-12/APC patch cords, and the corresponding NADDOD model is M4MPOA12FB\n. When the connection rate of both devices is 2x400G-4x200G, it is paired with two multimode OM4 MPO-2xMPO-4/APC patch cords, and the corresponding NADDOD model is M4MPOA2x4F."}},{"@type":"Question","name":"Why is the polished type of multimode patch cable used in the NDR module MPO/APC (Angled Polished Connector)?","acceptedAnswer":{"@type":"Answer","text":"100G-PAM4 optoelectronic devices are very sensitive to reflections occurring within the fiber, about 10% of the light is reflected back to the transmitter as it passes through the optical connector, distorting the data signal, APC's optical connector deflects this reflected light."}},{"@type":"Question","name":"What is the modulation method of the 800G Twin-Port NDR 2xSR4 optical module?","acceptedAnswer":{"@type":"Answer","text":"8-channels of 100G-PAM4 electrical modulation, Two ports of 4-channel 100G-PAM4 optical modulation."}},{"@type":"Question","name":"What is the transmission distance of the 800G Twin-Port NDR 2xSR4 optical module?","acceptedAnswer":{"@type":"Answer","text":"With the OM3 patch cable, the transmission distance is 30m, with the OM4 patch cable, the transmission distance is up to 50m."}},{"@type":"Question","name":"What are the heat dissipation methods of the NDR module?","acceptedAnswer":{"@type":"Answer","text":"One is with \"Finned Top\" and the other is \"Flat Top\"; Generally speaking, the \"Flat Top\" module is mainly used on the NIC side, because the thickness of the NIC is limited. The \"Finned Top\" module has a module top design with heat dissipation fins, which can increase heat dissipation capacity and improve module performance and reliability in high-temperature environments. It is usually used in Quantum-2 and Spectrum-4 air-cooled switches."}}],"breadcrumb":{"@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"InfiniBand NDR","item":"https://www.naddod.com/collections/infiniband-ndr"},{"@type":"ListItem","position":2,"name":"980-9I510-00NS00","item":"https://www.naddod.com/products/101489.html"}]}}
NADDOD OSFP-800G-2xSR4H is an InfiniBand and Ethernet 800Gb/s 2x400Gb/s Twin-port OSFP, SR8 multimode, parallel, 8-channel transceiver using two, 4-channel MPO-12/APC optical connectors at 400Gb/s each.The Twin-port SR8 transceiver is a key innovation with two internal transceiver engines enabling 64-ports of 400Gb/s in a 32-OSFP cage Quantum-2 switch. Spectrum-4 switches have 32 or 64 cages and enable 64-128 400G ports.
Specifications
Form Factor
Twin-port OSFP
Distance
30m (OM3) /50m (OM4)
Wavelength
850nm
Connector
Two MPO-12/APC
Power Consumption
≤16W
Transmitter
VCSEL
Receiver
PIN
Media
MMF
Modulation(electrical )
8x106.25Gb/s PAM4
Modulation(Optical )
Two ports 4x106.25Gb/s PAM4
Case Temperature(℃)
0~70°C(32 to 158°F)
Protocol
IB NDR,800G Ethernet Compliant
Applications
Product Highlights
Accelerating Al Networking Innovation with Dual Broadcom Chips
Advanced components ensure stable performance of optical modules, effectively preventing data transmission issues and guaranteeing the efficiency in AI model training.
Low BER on par with NVlDlA originals
During LL FEC (272,257) testing, NDD transceivers achieve Pre-FEC BER of -8~-10, and near-zero post-correction, reducing operations and maintenance (O&M) complexity and costs.
Different Heat Sink Designs Upgrade the Level of Performance
Mastering the differences between flat top and finned top, ensuring high performance and stable data transmission.
Why NADDOD
Module Availability
Worry-Free - Rigorous authentic testing!
Multi-version Device Compatibility
Multi-Version - Easy adaptation for each module!
High-Performance
Actual Test Data-Better results intuitively!
Our Approach
Test scene
NADDOD stringently selects a series of items in a professional testing environment to ensure the perfect blend of product performance and reliability. Including hardware compatibility (plugging, unplugging, rebooting), software compatibility (connectivity, parameters) and performance testing (DDM, BER, stability).
No matter the device version, the optical modules are rigorously tested to ensure seamless integration with various hardware and software versions.
Connectivity
Switch Side Testing
NIC Side Testing
Connectivity Testing
The module can connect to both devices normally, and the device port status is up.
BER
Switch Side Testing
NIC Side Testing
BER Testing
Tests REAL-TIME BER to ensure the accuracy of data transmission under high load conditions.
Questions & Answers
Ask a Question
Q:
Can I use only one port for the 800G Twin-Port NDR 2xSR4 optical module?
A:
Yes, if only one of the ports is used, the rate is 400G.
Q:
What are the differences between Flat Top modules and Finned Top modules?
A:
Flat Top module's height is 9.5 mm without heat sinks, relying on the heatsinks on the NIC ports to assist the module in cooling, which fits into compact or constrained spaces without interference. Finned Top modules feature a top design equipped with heat dissipation fins. The integrated top heatsink enhances cooling efficiency when handling massive data.
Q:
What kind of optical fiber do I need to use with the 800G Twin-Port NDR 2xSR4 optical module?
A:
When the connection rate of both devices is 2x400G-2x400G, it is paired with two OM4 MPO-12/APC patch cords, and the corresponding NADDOD model is M4MPOA12FB
. When the connection rate of both devices is 2x400G-4x200G, it is paired with two multimode OM4 MPO-2xMPO-4/APC patch cords, and the corresponding NADDOD model is M4MPOA2x4F.
Q:
Why is the polished type of multimode patch cable used in the NDR module MPO/APC (Angled Polished Connector)?
A:
100G-PAM4 optoelectronic devices are very sensitive to reflections occurring within the fiber, about 10% of the light is reflected back to the transmitter as it passes through the optical connector, distorting the data signal, APC's optical connector deflects this reflected light.
Q:
What is the modulation method of the 800G Twin-Port NDR 2xSR4 optical module?
A:
8-channels of 100G-PAM4 electrical modulation, Two ports of 4-channel 100G-PAM4 optical modulation.
Q:
What is the transmission distance of the 800G Twin-Port NDR 2xSR4 optical module?
A:
With the OM3 patch cable, the transmission distance is 30m, with the OM4 patch cable, the transmission distance is up to 50m.
Q:
What are the heat dissipation methods of the NDR module?
A:
One is with "Finned Top" and the other is "Flat Top"; Generally speaking, the "Flat Top" module is mainly used on the NIC side, because the thickness of the NIC is limited. The "Finned Top" module has a module top design with heat dissipation fins, which can increase heat dissipation capacity and improve module performance and reliability in high-temperature environments. It is usually used in Quantum-2 and Spectrum-4 air-cooled switches.
View Less
View More
Customer Reviews
5.0
3 Reviews
5 Star
100%
4 Star
0%
3 Star
0%
2 Star
0%
1 Star
0%
All Reviews (3)
r***6
Verified Purchase
r***6
Verified Purchase
5.0
I have used this transceiver on my QM9700 switch, and they are functioning well. In the near future, I may purchase more.
Helpful (8)Comments
u***s
Verified Purchase
u***s
Verified Purchase
5.0
I have received the test sample and have started using it. The module is working as expected, and there are currently no issues. It performs well and appears to be reliable.
Helpful (6)Comments
j***a
Verified Purchase
j***a
Verified Purchase
5.0
I had inquired with several suppliers about the MMA4Z00-NS optical module, but their delivery times were too long and couldn't meet our testing project requirements. Finally, I placed an order with NADDOD, and now I have received the shipment.
5.0
5.0
5.0