Features
- IBTA InfiniBand HDR compliant
- Up to 200Gb/s data rate
- 4x 50Gb/s PAM4 modulation
- SFF-8665 compliant
- Operating case temperature 0-70°C
- Single 3.3V supply voltage
- Bit Error Rate (BER) 1E-15 with InfiniBand systems
- Hot pluggable
- RoHS compliant
- LSZH (Low Smoke Zero Halogen) jacket
- LF (Lead Free) HF (Halogen Free) PCB
- SFF-8636 compliant I2C management interface
Description
Q56-200G-DACH cables are high speed, cost-effective alternatives to fiber optics in 200Gb/s InfiniBand HDR applications.
Q56-200G-DACH passive copper cable contains eight high-speed copper pairs, each operating at data rates of up to 50Gb/s.Each QSFP56 port comprises an EEPROM providing product information, which can be read by the host system.
NADDOD’s unique quality passive copper cable solutions provide power-efficient connectivity for short distance interconnects It enables higher port bandwidth, density and configurability at a low cost and reduced power requirement in the data centers. Rigorous cable production testing ensures best out-of-the-box installation experience, performance and durability.
Absolute Maximum Ratings
Table1-Absolute Maximum Ratings
Parameter | Min. | Typical | Max. | Unit | Notes |
---|---|---|---|---|---|
Storage Temperature | -40 | - | +85 | ºC | |
Supply voltage | -0.3 | - | 3.6 | V | |
Data input voltage | -0.3 | - | 3.6 | V | |
Control input voltage | -0.3 | - | 3.6 | V |
Operational Specifications
Table2-Operational Specifications
Parameter | Min. | Typical | Max. | Unit | Notes |
---|---|---|---|---|---|
Supply voltage (Vcc) | 3.135 | 3.3 | 3.465 | V | |
Power consumption | - | - | 0.1 | W | |
Operating case temperature | 0 | - | 70 | ℃ | |
Operating relative humidity | 5 | - | 85 | % |
Electrical Specifications

Table3-Electrical Specifications
Parameter | Min. | Typical | Max. | Unit | Notes |
---|---|---|---|---|---|
Characteristic impedance | 90 | 100 | 110 | Ω | |
Time propagation delay (informative) | - | - | 4.5 | ns/m |
Mechanical Specifications
Length (m) | Cable AWG | Single Cable Diameter | Minimum Bend Radius |
---|---|---|---|
1 | 30 | 7.1 ± 0.35mm | Single bend: 35.5mm Assembly/repeated bend: 71mm |
2 | 26/30 | 7.1 ± 0.35mm/9.4 ± 0.4mm | Single bend: 35.5/47mm Assembly/repeated bend: 71/ 94mm |
3 | 26 | 9.4 ± 0.4mm | Single bend: 47mmAssembly/repeated bend: 94mm |
Regulatory Compliance
Table4-Regulatory Compliance
Feature | Test Method | Performance |
---|---|---|
Electrostatic Discharge (ESD) to the Electrical Pins | MIL-STD-883C Method 3015.7 | Class 1(>2000 Volts) |
Electromagnetic Interference(EMI) | FCC Class B/CENELEC EN55022 Class B/CISPR22 ITE Class B | Compliant with Standards |
RF Immunity(RFI) | IEC61000-4-3 | Typically Show no Measurable Effect from a 10V/m Field Swept from 80 to 1000MHz |
RoHS Compliance | RoHS Directive 2011/65/EU and it’s Amendment Directives 6/6 | RoHS 6/6 compliant |
Part Numbers and Descriptions
Table5-Part Numbers and Descriptions
Part Number | Description |
---|---|
Q56-200G-CU0-5H | Passive Copper cable, IB HDR, up to 200Gb/s, QSFP56, LSZH, 0.5m, black pulltab, 30AWG |
Q56-200G-CU1H | Passive Copper cable, IB HDR, up to 200Gb/s, QSFP56, LSZH, 1m, black pulltab, 30AWG |
Q56-200G-CU1-5H | Passive Copper cable, IB HDR, up to 200Gb/s, QSFP56, LSZH, 1.5m, black pulltab, 30AWG |
Q56-200G-CU2H | Passive Copper cable, IB HDR, up to 200Gb/s, QSFP56, LSZH, 2m, black pulltab, 26AWG |
Warnings
Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow guidelines according to proper ESD procedures.
Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation.
Datasheet: 200G QSFP56 InfiniBand HDR Direct Attach Passive Copper Cable